Model |
R5-3K-S2 |
R5-4K-S2 |
R5-5K-S2 |
R5-6K-S2 |
R5-7K-S2 |
R5-8K-S2 |
Input(DC) |
Max.PV Array Power [Wp]@STC |
4500 |
6000 |
7500 |
9000 |
10500 |
12000 |
Max. DC Voltage [V] |
600 |
MPPT Voltage Range [V] |
90-550 |
Nominal DC Voltage[V] |
360 |
Start Voltage [V] |
100 |
Min. DC Voltage [V] |
80 |
Max. DC Input Current [A] |
12.5/12.5 |
25/12.5 |
Number of DC Connection Sets per MPPT |
1/1 |
2/1 |
Number of MPPT |
2 |
DC Switch |
Integrated |
Output (AC) |
Rated AC Power [W] |
3000 |
4000 |
5000*1 |
6000 |
7000 |
8000 |
Max. AC Power*1[VA] |
3300 |
4400 |
5500 |
6000 |
7700 |
8000 |
Rated AC Current [A]@230Vac |
13.1 |
17.4 |
21.8*1 |
26.1 |
30.5 |
34.8 |
Max. AC Current [A] |
14.4 |
19.2 |
24 |
26.1 |
33.5 |
34.8 |
Nominal AC Voltage/ Range [V] |
220,230,240/180-280 |
Grid Frequency/ Range [Hz] |
50,60/45-55,55-65 |
Power Factor [cos φ] |
0.8 leading~0.8 lagging |
Total Harmonic Distortion [THDi] |
< 2%(at nominal power) |
Feed-in |
L+N+PE |
Efficiency |
Max. Efficiency |
97.8% |
98.0% |
98.1% |
98.2% |
98.2% |
98.3% |
Euro Efficiency |
97.2% |
97.5% |
97.6% |
97.6% |
97.7% |
97.8% |
MPPT Accuracy |
>99.9% |
Protection |
Internal Over-voltage Protection |
Integrated |
DC Insulation Monitoring |
Integrated |
DC Surge Protection |
Integrated |
Grid Monitoring |
Integrated |
AC Short Circuit Current Protection |
Integrated |
AC Grounding Detection |
Integrated |
GFCI Monitoring |
Integrated |
DCI Monitoring |
Integrated |
AC Surge Protection |
Integrated |
Thermal Protection |
Integrated |
Anti-island protection monitoring |
AFD |
Interface |
DC Connection |
MC4 |
AC Connection |
Plug-in connector |
Terminal Block |
Human Machine Interface |
LED+(bluetooth/Wi-Fi+APP) |
Communication Port |
RS232(USB joints)+RS485(RJ45 crystal joints) |
Communication Mode |
Wi-Fi/GPRS/4G(Optional) |
General Data |
Topology |
Transformerless |
Consumption at Night [W] |
<0.2 |
Consumption at Standby [W] |
6 |
Operating Temperature Range |
-40°C to +60°C (running in reduced load condition when the temperature is above 45°C) |
Cooling Method |
Natural Convection |
Ambient Humidity |
0-100% Non-condensing |
Altitude |
4000m(>3000m power derating) |
Noise [dBA] |
<25 |
Ingress Protection |
IP65 |
Mounting |
Rear Panel |
Dimensions [H*W*D][mm] |
389*367*143 |
429*418*177 |
Weight [kg] |
12.2 |
18 |
Standard Warranty [Year] |
5 (standard)/10/15/20/25 (Optional) |
Applicable Standard |
IEC62109-1/2,IEC61000-6-1/2/3/4,EN50438,C10/C11,IEC62116,IEC61727,RD1699,UNE 206006, UNE 206007,CEI 0-21,AS4777.2,NBR 16149, NBR 16150,VDE-AR-N 4105 |
Remarks: *1 According to VDE - ARN - N 4105, Rated AC Power for R5-5K-S2 is 4600VA; According to AS4777, Rated AC Power for R5-5K-S2 is 4999VA. *2 According to C10/C11, Max. AC Power = Rated AC Power *3 According to VDE - ARN - N 4105, Rated AC Current for R5-5K-S2 is 20A; According to AS4777, Rated AC Current for R5-5K-S2 is 21.7A. |