Features:
Max. efficiency 98.8%
Wide voltage range and low startup voltage
3/4 MPPT design with precise MPPT algorithm
THDi<3%, low harmonic distortion against grid
Anti-resonance, supporting over 6MW parallelled in one transformer
Perfect commercial site monitoring solution
130% DC overload ratio, 13A input for each PV string
Strings intelligent monitoring, Smart I-V curve scan
Fuse free design to avoid fire hazard
Type II surge arrester for both DC and AC
Natural convection, Fan-less design, longer lifes
Leakage current repression technology
Volt-watt work mode integrated
DC input reverse alarm
Intergrated Export Power Manager (EPM)
Datasheet
Model Name |
Solis-25K-5G |
Solis-30K-5G |
Solis-33K-5G |
Solis-36K-5G |
Solis-40K-5G |
Solis-40K-HV-5G |
Solis-50K-HV-5G |
Input DC
Recommended max. PV power |
33kW |
39kW |
43kW |
47kW |
52kW |
52kW |
65kW |
Max. input voltage |
1100V |
Rated voltage |
600V |
Start-up voltage |
180V |
MPPT voltage range |
200-1000V |
Max. input current |
26A/26A/26A |
4*26A |
Max. short circuit current |
40A/40A/40A |
4*40A |
MPPT number/Max. input strings number |
3/6 |
4/8 |
Output AC
Rated output power |
25kW |
30kW |
33kW |
36kW |
40kW |
40kW |
50kW |
Max. apparent output power |
27.5kVA |
33kVA |
36.3kVA |
39.6kVA |
44kVA |
44kVA |
55kVA |
Max. output power |
27.5kW |
33kW |
36.3kW |
39.6kW |
44kW |
44kW |
55kW |
Rated grid voltage |
3/N/PE, 220/380V, 230/400V |
3/PE, 480V |
Rated grid frequency |
50/60Hz |
Rated grid output current |
38.0A/36.1A |
45.6A/43.3A |
50.1A/47.6A |
54.7A/52.0A |
60.8A/57.7A |
48.1A |
60.1A |
Max. output current |
41.8A |
50.2A |
55.1A |
60.2A |
66.9A |
53.0A |
66.2A |
Power Factor |
>0.99 (0.8 leading - 0.8 lagging) |
THDi |
<3% |
Efficiency
Max. efficiency |
98.8% |
EU efficiency |
98.3% |
Protection
DC reverse-polarity protection |
Yes |
Short circuit protection |
Yes |
Output over current protection |
Yes |
Surge protection |
DC Type II / AC Type II |
Grid monitoring |
Yes |
Anti-islanding protection |
Yes |
Temperature protection |
Yes |
Strings monitoring |
Yes |
I/V Curve scanning |
Yes |
Anti-PID function |
Optional |
Integrated AFCI (DC arc-fault circuit protection) |
Yes |
Integrated DC switch |
Optional |
General Data
Dimensions (W*H*D) |
647*629*252 mm |
Weight |
45kg |
Topology |
Transformerless |
Self consumption |
<1W (night) |
Operating ambient temperature range |
-25 ~ +60°C |
Relative humidity |
0-100% |
Ingress protection |
IP65 |
Cooling concept |
Natural convection |
Max. operation altitude |
4000m |
Grid connection standard |
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, IEC61727, DEWA |
Safety/EMC standard |
IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4 |
Features
DC connection |
MC4 connector |
AC connection |
OT terminal |
Display |
LCD |
Communication |
RS485, Optional: Wi-Fi, GPRS |